Specifications for ACS 600 SingleDrive
Robust cabinet, which is suitable for various industrial environments, encloses high performance drives with IGBT and DTC technology.

Main Connection
3 Phase Supply Voltage: U2IN = 208...240 V ± 10 %
U3IN = 380...415 V ± 10 %
U5IN = 380...500 V ± 10 %
U6IN = 525...690 V ± 10 %
Frequency: 48...63 Hz
Short Circuit Capacity: 50 kA 1 s
Power Factor: cos1 = 0.97 (fundamental)
cos  = 0.93...0.95 (total)
Enclosure
Degree of Protection: IP 21 (Standard for ACS 607)
IP 22 (Standard for ACS 601, Optional for ACS 607)
IP 42 (Optional)
IP 54 (Optional, derating required
for ACS 601)
IP 54R (R = flange for air duct,
optional only for frames R11i and larger)
Paint Color: ACS 601/604
Light beige NCS 1502-Y (RAL 90021/PMS 420C), Black ES 900
(ACS 601 Frame sizes R2...R6)

ACS 607
Light beige RAL 7035 semi gloss
Efficiency
At Nominal Power: 98 %
 
Motor Connection
3 Phase Output Voltage 0...U2IN/3IN/5IN/6IN
Frequency Control 0...±300 Hz
0...±120 Hz with du/dt filters
Field Weakening Point: 8...300 Hz
Motor Control Software: ABB's Direct Torque Control (DTC)
Torque Control: Torque step rise time
Open Loop <5 ms with nominal torque
Closed Loop <5 ms with nominal torque
Non-linearity:
Open Loop ±4 % with nominal torque
Closed Loop ±1 % with nominal torque
Speed Control Static accuracy
Open Loop 10 % of the motor slip
Closed Loop 0.01 % of the nominal speed
Dynamic accuracy
Open Loop 0.3...0.4 %sec. with 100 % torque step
Closed Loop 0.1...0.2 %sec. with 100 % torque step
Environmental Limits
Ambient Temperature: Transportation: -40...+70 °C
Storage:           -40...+70 °C
Stationary use:  0...+40 °C
(+50 °C by derating, see figure below)
Relative Humidity: 5...95 %, no condensation allowed
Cooling Method Dry Clean Air
Altitude: 0...1000 m ASL No derating required.
1000...4000 m ASL Derating required.

Imax = IN,40C Multiply (100 % - 1 % Multiply Divide + x Multiply (40°C - Tamb))
x = 1,5 % / °C ACS 607
x = 3,5 % / °C ACS 601
h = altitude above sea level > 1000 m
IN,40C = ACS 600 nominal current at 40 °C
Tamb = maximum ambient temperature, Note: Imax < or = IN,40C